Purified Water System Manufacturer
- USP, FDA, Ph. Eu., JP, and cGMP compliant
- Protects product quality and safety
- For factories, research labs, cleanrooms, and more
- Made with 20+ years of water purification experience
- 1-year warranty and lifetime technical assistance
- RO, DI, UF, EDI, and other treatment technologies
Purified Water System Applications
ere at SaintyCo, our systems provide pharma-grade purified water in research and manufacturing facilities for product formulation, equipment cleaning, and more. We serve the pharmaceutical, cosmetics, personal care, nutraceutical, food and beverage, chemical, and biotechnology industries, among others.

What Is A Purified Water System?
A purified water system is a water treatment solution that removes various contaminants and compounds to produce extremely high-purity water. It’s an essential piece of kit for manufacturing environments, research laboratories, and cleanrooms. Without it, particles in the water could cause pipe blockages, damage machinery, and make final products unsafe at worst, or at best, unstable.
At SaintyCo, we’ve engineered an array of purifying water systems to clean water of particulates, bacteria, organics, pyrogens, and ions. Our systems are designed to produce, store, and distribute water that complies with global pharmacopeia standards. The pure water is used for things like washing product containers, rinsing equipment, feeding water for injection (WFI) systems, and the general preparation and formulation of apyrogenic and sterile medicines.
Types Of Purified Water Systems
We offer a wide range of advanced water purification technologies that can be combined to suit every possible use case and desired result.

Uses semi-permeable membranes to remove dissolved salts and minerals.

Our chemical-free processing system is suitable for continuous purification.

Ion-exchange resins remove cations, like calcium and sodium, and anions, like chloride and sulfate.

Targets particles with a high molecular weight (like bacteria and endotoxins) post-RO or EDI.

Our thermal desalination units with multiple boiling stages are commonly used for WFI.

Uses 185/254 nm UV lamps to kill microbes and degrade trace organics without chemicals.

Energy-efficient mechanical compression, ideal for high-capacity setups.

Our two-stage RO systems improve water quality, conductivity, and microbial control.
Top Purified Water Systems
Below are some of our most commonly requested water purification solutions. Need something else? Contact the SaintyCo team, and we’ll give you a custom quote.
Ultrapure Water SystemUses multiple processing stages to achieve the lowest levels of conductivity and extreme purity.
USP Water Purification SystemPurification and distribution systems that meet United States Pharmacopeia standards.
Skid-mounted Water Purification SystemPre-assembled mobile units ready for use, with customizable layout and modules.
Fixed Purified Water SystemPurpose-engineered systems for permanent integration into your infrastructure.
SaintyCo Purified Water System Features
Our industrial water purification units come with a host of desirable features and benefits, from industry-leading sustainability standards to long operational lifespans.

Meet international standards and regulations, like cGMP and USP.

Our solutions cover everything from pharma to food and cosmetics.

Skid-mounted options for user-friendly mobility.

Energy efficient pumps minimize environmental impact.

Combine RO, EDI, UVA and other technologies in one system.

Fully automated systems with PLCs and HMIs for consistency.

Robust construction for reliable output under continuous operation.

Self-cleaning or easy-access filters with modular parts reduce downtime.
Purified Water System Stages
With SaintyCo, every stage of the water purification process is fully optimized. Each step involves high grade components and customizable options de

The first processing stage involves components like filters to remove sediment and particles, plus softeners and dosing systems, depending on raw water quality.

For post-RO polishing, most SaintyCo systems use electrodeionization units, which are ideal for producing USP-grade water without using chemicals.

Our units maintain water purity in a continuous loop piping system with sanitary-grade storage tanks and flow and pressure control valves.

At the main stage, reverse osmosis, ultrafiltration, or nanofiltration systems remove dissolved solids, ions, and microbial contaminants.

For biological safety, our systems include UV sterilizers to destroy bacteria and viruses, submicron filters, optional ozonation units, and heat or chemical sanitization.

SCADA or PLC panels display and log live data from temperature and flow sensors, TOC analyzers, and conductivity and resistivity meters (with remote monitoring).
Filtration Types
SaintyCo purified water systems are available with a diverse range of filtration technologies. Depending on your needs, we offer depth filters, bag filter, and automatic backwash pre-filters. For fine filtration, our products include pleated membranes, cartridge filters, and tangential flow filtration (TFF). Our options for polishing filters include activated carbon, magnetic filters, and UF membranes.


Compliance And Validation
Our engineers here at SaintyCo have designed our innovative water purification systems to meet stringent pharma and biotech standards. Our units comply with USP <1231>, GMP, and FDA 21 CFR Part 11 requirements for electronic records and audit trails.
Our Resources

Browse the SaintyCo product catolog which contains all the various types of water filtration systems on offer and details of our services.

Download our specifications sheet for an overview and comparison of our water purifier units’ capabilities and performance metrics.

Watch this short video explainer showing SaintyCo water purification systems in action, highlighting each stage of the process.
Why Choose SaintyCo For Your Purified Water System


SaintyCo has earned itself a fantastic reputation over the course of two decades, having delivered thousands of successful purified water system projects. So, if you’re looking for a partner with deep water purification expertise, SaintyCo should be your first choice.
Not only do we have one of the industry’s most diverse product catalogs when it comes to purified water systems, but we can also offer customized designs tailored to your specific needs. Plus, we guarantee fair, transparent pricing that makes it easy to achieve your water purification goals within budget.
Best-Selling Purified Water Systems
SaintyCo purified water systems are some of the top-performing products on the market today. For more information about specific models, please reach out to our knowledgable support team.

Our ZLD systems are designed to reduce wastewater by treating it to remove impurities, then recycling it to be reused. It’s an essential process for modern manufacturing companies adhering to environmental standards.

Our CIP water purification skid combines a purified water loop with an automated CIP process. It uses hot water for sterilizing and cleaning tanks, piping, and process lines without dismantling the equipment.

We offer water purification systems with dedicated storage tanks (typically stainless steel or HDPE), ideal for situations where demand fluctuates. Or, where purified water must be available immediately on startup.

SaintyCo self-cleaning systems are ideal for modules positioned in remote or hard-to-reach areas. They use backwashing, flushing, and automated cleaning cycles to reduce fouling and save time-consuming manual intervention.
Integrated And Portable Models
Whether you need a purified water system ready for flexible deployment or permanent integration, SaintyCo has standard and custom solutions to align with your application.
Work with our engineers to develop a fixed purified water system for your unique processing line. Our permanent installations integrate with pre-defined manufacturing setups. Typically, these systems give you higher flow rates and support more complex configurations like multi-stage filtration and hot water sanitization.
We offer several types of mobile water purification systems, mounted on skids or trolleys to make them portable around the warehouse, lab, or factory floor. They’re ideal for pilot plants, utility upgrades, or backup during main equipment maintenance periods. They are ready to use with minimal installation time.
More About Our Purified Water Systems
Find out more about the main categories of SaintyCo water purification systems, including average technical performance ranges, pictures of recent projects, and more.
- Data Sheet
- After-Sales Service
| Standard Purified Water System | Ultrapure Water System | Skid-Mounted Water System | |
| Flow Rate | 500-10,000 L/h | 100-5,000 L/h | 200-2,000 L/h |
| Conductivity / Resistivity | 1–10 µS/cm | ≥18 MΩ·cm | 0.5–5 µS/cm |
| TOC (Total Organic Carbon) | <500 ppb | <10 ppb | <300 ppb |
| Bacterial Count | <100 CFU/mL | <1 CFU/mL | <50 CFU/mL |
| Endotoxin Level | <0.25 EU/mL | <0.03 EU/mL | <0.25 EU/mL |
| pH Range | 6.0-8.0 | 5.5-7.5 | 6.0-8.0 |
| Pre-Treatment Modules | Multimedia, carbon, softener | Advanced pre-treatment + UF | Compact pretreatment unit |
| Primary Purification | RO + EDI | RO + EDI + UV + UF | RO or RO + EDI |
| Polishing Stages | UV Optional | Required | UV Optional |
| Portable | Optional | No | Yes |
We treat every client with dedicated time, care and respect—even long after purchase. You’ll get our lifetime after-sales service included with your purified water system, so even if you have a technical question years down the line, we’ll be on hand to help.
Aside from technical queries, we can also assist with process optimization, spare parts, maintenance, and more. We also provide full DQ, IQ, OQ, and PQ documentation. Plus, anything you need for regulatory inspection, like weld logs, calibration certificates, and material traceability.
Reverse osmosis (RO) is a technique of filtering water through a semi-permeable membrane to remove most dissolved solids. Deionization (DI) uses ion exchange to remove charged ions after RO which gives a higher purity. Water for injection (WFI) must be further distilled of vapor compressed to be acceptable for parenteral use.
Purified water (PW) and water for injection (WFI) are produced using different methods. SaintyCo has systems that will achieve both outcomes, in separate units. PW is generally made via RO + EDI whereas WF needs multi-effect distillation or vapor compression to meet global standards.
There are many factors at play here, including the initial water quality and how heavily the system is used. As a guidelines, pre-filters may need changing around 3-6 months, RO membranes every 1-2 years, UV lamps annually, and EDI modules every 3-5 years. Our units include monitoring tools to alert you.
Related Products
Powder Filling LineDelicate and precise filling of fine powder products like food or makeup.
Clean Room DuctingManage airflow in controlled, hygienic, and sterile environments.
Clean Room FloorEpoxy, self-leveling, raised, rubber, and more types of cleanroom floors.
Bottle Filling LineFrom cosmetics to pharma, everything you need for filling bottles.
Water Quality And Grades
At SaintyCo, our purified water systems produce water that meets global quality specs in industries like pharma, biomedical, and food industries. This includes configurations to satisfy various standards and regulations, including:
- USP: US Pharmacopeia for non-perenternal pharmaceutical use with conductivity <1.3 µS/cm at 25°C
- ASTM Type 1,2, 3: Type 1 (ultrapure) used for HPLC, Type 2 for general lab prep, and Type 3 for rinsing
- CLRW (Clinical Laboratory Reagent Water): Follows CLSI standards for clinical diagnostics like hematology
- AAMI ST108: For sterile processing and medical device reprocessing
- HPLC-grade: Extremely low TOC (<10 ppb), <1 µS/cm, and <1 cfu/mL
Whatever your use case, SaintyCo has an appropriate system that’s audit-ready.
Distribution Loop And Return Flow
We’ve engineered high-efficiency loops that maintain flow velocity, minimize dead legs and prevent microbial buildup. Our design principles include constant recirculation at ≥1.5 m/s. This prevents stagnation. Sloped piping makes sanitization easier and enables full draining. To further reduce spots where microbes could fester, our systems have zero dead leg valves and use orbital welded joints, so the inside surface is smooth and free of crevices. We also offer double piping systems and balanced return pressure using VFD pumps and automated balancing valves. Our various loop designs cover both hot or ambient systems.
Yes, we manufacture PW systems for ot water sanitization, generally around 80 to 85°C. Some of our models are compatible with other protocols like chemical sanitization, so if you have a custom request please let us know.
Because we offer such a massive variety of products with various price-altering specifications, we quote customers based on their requests. For a tailored quote, please contact us directly.
Yes, SaintyCo water purifying systems come with PLC panels from major brands like Siemens. Also they support standard communication protocols ilke Modbus, OPC UA, and Ethernet/IP.
Our systems include features like TOC analyzers, temperature probes, and conductivity meters. Most models also come with sampling valves for regular microbial testing.
Systems are designed for ASME BPE guidelines, sp piping is fully drainable and all wetted parts are made from 316L stainless steel. Our units typically use orbital welding and EDPM or PTFE gaskets.